    Spectroscopic prism
    Beam splitting prism A film is plated on the inclined surface of the right Angle prism, and then a same right Angle prism is glued to form a cubic beam splitting prism. The astigmatism of the plate spectroscope can be avoided, and the coating is not directly exposed, which is not easy to damage and corrosion. When transmitting light, the beam splitting prism has no influence caused by light deflection, so there is no beam translation, ghost image and interference. For spectroscopy and imaging. Long calibration time is not required at 45° incidence. When the light is incident on the vertical incidence plane, the outgoing light is divided into two polarized beams. Where P light is transmitted light and S light is reflected light. The original proportional relationship between horizontal polarization and vertical polarization in the incident years can be maintained equally after the beam splitting prism.
    Product inquiry PDF Download
    Product details

    Brand: Outai Optics

    Series: Prism series

    Type: Splitting prism

    Beam splitting prism A film is plated on the inclined surface of the right Angle prism, and then a same right Angle prism is glued to form a cubic beam splitting prism. The astigmatism of the plate spectroscope can be avoided, and the coating is not directly exposed, which is not easy to damage and corrosion. When transmitting light, the beam splitting prism has no influence caused by light deflection, so there is no beam translation, ghost image and interference. For spectroscopy and imaging. Long calibration time is not required at 45° incidence. When the light is incident on the vertical incidence plane, the outgoing light is divided into two polarized beams. Where P light is transmitted light and S light is reflected light. The original proportional relationship between horizontal polarization and vertical polarization in the incident years can be maintained equally after the beam splitting prism.

    Product specification
    Technical parameterMaterialK9, etc
    Angle tolerance

    90°±10" Arcsec

    Dimensional tolerance

    ±0.02

    Light aperture 

    90%Central Area

    Face type

    1/10λ@633nm

    Surface quality

    60/40,40/20,20/10or better

    Air gap

    0.003-0.008mm

    Coating film

    AR Membrane、

    Pyramid error

    <1'

    Application scenario

    Projector, optical instrument, fingerprint instrument, alignment instrument, rangefinder, image finder, mechanical sight, solar converter, rangefinder, erecting telescope, laser treatment equipment, laser measuring system, etc

    Without
    Without